{"id":9868,"date":"2017-11-20T07:00:34","date_gmt":"2017-11-20T06:00:34","guid":{"rendered":"https:\/\/www.gok-blog.de\/2017\/11\/20\/how-can-i-check-the-functionality-of-the-limit-indicator\/"},"modified":"2026-06-15T08:39:05","modified_gmt":"2026-06-15T06:39:05","slug":"how-can-i-check-the-functionality-of-the-limit-indicator","status":"publish","type":"post","link":"https:\/\/www.gok-blog.de\/en\/how-can-i-check-the-functionality-of-the-limit-indicator\/","title":{"rendered":"How can I check the functionality of the limit indicator?"},"content":{"rendered":"<p style=\"text-align: justify;\">In principle, it eliminates the possibility of overfilling a fuel oil tank. First, the tank truck driver must determine the free capacity \u2013 for example, they can do this using the SmartBox<sup>\u00ae<\/sup>. Based on this value, the mineral oil retailer knows how many litres of fuel oil fit into the tank. If they have miscalculated or the filling level indicator is not displaying correctly, the limit indicator still provides protection. But how do you ensure that the limit indicator will definitely respond when it comes to it?<!--more--><\/p>\n<figure id=\"attachment_8988\" aria-describedby=\"caption-attachment-8988\" style=\"width: 146px\" class=\"wp-caption alignleft\"><a ref=\"magnificPopup\" href=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/1509700.jpg\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"wp-image-8988\" src=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/1509700.jpg\" alt=\"Pr\u00fcfger\u00e4t F-Stop\u00ae GWG-PG 1 f\u00fcr Grenzwertgeber in Heiz\u00f6ltanks.\" width=\"146\" height=\"283\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/1509700.jpg 195w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/1509700-155x300.jpg 155w\" sizes=\"(max-width: 146px) 100vw, 146px\" \/><\/a><figcaption id=\"caption-attachment-8988\" class=\"wp-caption-text\"><strong>F-Stop\u00ae GWG-PG 1<\/strong><\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">The limit indicator test device type F-Stop<sup>\u00ae<\/sup> GWG-PG 1 provides safety. For example, this device allows a specialised company to carry out a test to determine whether the safety device functions correctly against overfilling. The <strong>function check of the limit indicator is prescribed<\/strong> as part of a one-off and recurring inspection of the fuel oil system according to AwSV. However, the fitting does not have to be disassembled and removed from the tank.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"en_beitrag_box\">\n<p><span class=\"en_like_h3\">You might also be interested in<\/span><\/p>\n<p>Discover more helpful content on this topic.<\/p>\n<p><a href=\"#weiterfuehrend\">See related posts<\/a><\/p>\n<\/div>\n<h2><span class=\"ez-toc-section\" id=\"Special_requirement_for_older_limit_indicators\"><\/span>Special requirement for older limit indicators<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"text-align: justify;\">Only in the case of existing fuel oil consumer installations with <strong>limit indicator in hole design<\/strong>, a visual check must be carried out at least once a year.<\/p>\n<p style=\"text-align: justify;\">Section 46 AwSV stipulates that the operator must perform regular function checks on a safety device.Normally, it is the case that the tank truck driver carries out this check during filling.<\/p>\n<figure id=\"attachment_8984\" aria-describedby=\"caption-attachment-8984\" style=\"width: 756px\" class=\"wp-caption aligncenter\"><a ref=\"magnificPopup\" href=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/10\/LKW-Tank.jpg\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"wp-image-8984 size-full\" src=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/10\/LKW-Tank.jpg\" alt=\"Vor der Betankung muss der Tankwagenfahrer den Grenzwertgeber auf Funktion pr\u00fcfen.\" width=\"756\" height=\"491\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/10\/LKW-Tank.jpg 756w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/10\/LKW-Tank-300x195.jpg 300w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/10\/LKW-Tank-705x458.jpg 705w\" sizes=\"(max-width: 756px) 100vw, 756px\" \/><\/a><figcaption id=\"caption-attachment-8984\" class=\"wp-caption-text\"><strong>Before refuelling, the tank truck driver must check the function of the limit indicator.<\/strong><br \/>\u00a9 J\u00fcrgen F\u00e4lchle \/ fotolia.com<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Contracting_a_specialist_company\"><\/span>Contracting a specialist company<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"text-align: justify;\">However, if the operator of a fuel oil system has no qualified or competent personnel, they should contract a specialist company to carry out the function check on the limit indicator.The special focus is on checking the <strong>shut-down time of the limit indicator<\/strong>. This is clearly defined according to EN 13616 in order to rule out overfilling.<\/p>\n<p style=\"text-align: justify;\">Various types and brands of limit indicator checking and test devices are available on the market.To check the functionality, we recommend the test device type F-Stop<sup>\u00ae <\/sup>GWG-PG 1. The simpler test devices are <strong>no longer sufficient to meet the requirement<\/strong> for shut-down time.<\/p>\n<h2 style=\"text-align: justify;\"><span class=\"ez-toc-section\" id=\"The_check_takes_place_as_follows\"><\/span>The check takes place as follows:<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul style=\"text-align: justify;\">\n<li style=\"text-align: left;\">The specialist fitter connects the coupling socket of the test device with the connector of the limit indicator. The coupling socket fits the common fittings, such as <a href=\"https:\/\/gok.de\/en\/Grenzwertgeber-GWD-Z150-0-5m-Kabel-1508112?search=grenzwertgeber\" target=\"_blank\" rel=\"noopener noreferrer\">type GWD<\/a> and <a href=\"https:\/\/gok.de\/en\/Grenzwertgeber-GWS-Z400mm-AG-G1-Rohrarmatur-904-1560440?search=grenzwertgeber\" target=\"_blank\" rel=\"noopener noreferrer\">type GWS<\/a>.<\/li>\n<li style=\"text-align: left;\">The tester then starts the heating process by pressing and holding the &#8220;TEST&#8221; button.<\/li>\n<li style=\"text-align: left;\">If the PTC thermistor heats up properly, the LED display changes to enable.<\/li>\n<\/ul>\n<figure id=\"attachment_8985\" aria-describedby=\"caption-attachment-8985\" style=\"width: 531px\" class=\"wp-caption aligncenter\"><a ref=\"magnificPopup\" href=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/Oel_Pruefgeraet-fuer-GWG_15.jpg\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"wp-image-8985 size-full\" src=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/Oel_Pruefgeraet-fuer-GWG_15.jpg\" alt=\"Der Fachmann hat das Grenzwertgeber-Pr\u00fcfger\u00e4t F-Stop PG 1 mit der Kupplungsdose des Grenzwertgebers gekoppelt und pr\u00fcft dessen Funktionsf\u00e4higkeit am Heiz\u00f6ltank\" width=\"531\" height=\"300\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/Oel_Pruefgeraet-fuer-GWG_15.jpg 531w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2017\/11\/Oel_Pruefgeraet-fuer-GWG_15-300x169.jpg 300w\" sizes=\"(max-width: 531px) 100vw, 531px\" \/><\/a><figcaption id=\"caption-attachment-8985\" class=\"wp-caption-text\"><strong>The specialist has coupled the limit indicator test device F-Stop PG 1 with the coupling socket of the limit indicator and is checking its function.<\/strong><\/figcaption><\/figure>\n<p style=\"text-align: justify;\">With the &#8220;enable&#8221; display, the safety fitting fulfils its electrical default values during this simple test. A bit more time-consuming, but all the more important is checking the shut-down time in the so-called <strong>dry-wet test<\/strong> to check the function. For this, the limit indicator must be disassembled and immersed in the operating medium.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Replace_if%E2%80%A6\"><\/span>Replace if&#8230;<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"text-align: justify;\">The time in which the limit indicator sends the shut-down signal to the overfill prevention must <strong>not exceed 1.5 seconds<\/strong>. On the display of the F-Stop<sup>\u00ae<\/sup> GWG-PG 1, the tester can read how many seconds the safety device needed for shut-down. If the shut-down time is over 1.5 seconds, the limit indicator must be replaced immediately.<\/p>\n<p style=\"text-align: justify;\">More information on the F-Stop<sup>\u00ae<\/sup> GWG-PG 1 can be found in the <a href=\"https:\/\/gok.de\/en\/Pruefgeraet-f.-Grenzwertgeber-F-Stop-GWG-PG1-1509700?search=grenzwertgeber\" target=\"_blank\" rel=\"noopener noreferrer\">product description on the GOK website<\/a> and in the <a href=\"https:\/\/gok.de\/media\/6c\/a3\/6c\/1714739648\/1509750_GWGTPG1_DE.pdf?ts=1730343686\" target=\"_blank\" rel=\"noopener noreferrer\">operating manual<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The limit indicator protects the fuel oil tank from possible overfilling. But how can you ensure that the safety device actually functions if required?<\/p>\n","protected":false},"author":8,"featured_media":8986,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[398],"tags":[434,350,306,349,332],"ausgabe":[],"class_list":["post-9868","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tank-liquid-media","tag-awsv","tag-heating-oil-tank","tag-limit-indicator","tag-overfill-sensor","tag-safety-equipment"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9868","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/comments?post=9868"}],"version-history":[{"count":1,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9868\/revisions"}],"predecessor-version":[{"id":14538,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9868\/revisions\/14538"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/media\/8986"}],"wp:attachment":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/media?parent=9868"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/categories?post=9868"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/tags?post=9868"},{"taxonomy":"ausgabe","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/ausgabe?post=9868"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}