{"id":9873,"date":"2018-04-23T07:00:43","date_gmt":"2018-04-23T05:00:43","guid":{"rendered":"https:\/\/www.gok-blog.de\/2018\/04\/23\/what-is-mandatory-for-gas-barbecues-operated-commercially\/"},"modified":"2026-06-15T08:03:34","modified_gmt":"2026-06-15T06:03:34","slug":"what-is-mandatory-for-gas-barbecues-operated-commercially","status":"publish","type":"post","link":"https:\/\/www.gok-blog.de\/en\/what-is-mandatory-for-gas-barbecues-operated-commercially\/","title":{"rendered":"What is mandatory for gas barbecues operated commercially?"},"content":{"rendered":"<p style=\"text-align: justify;\">Already used in the USA and on the rise in Germany as well: the gas barbecue. If you use the barbecue privately, the appropriate fittings (pressure reducer, hose assembly) are already included in delivery. But which pressure regulator or hose assembly do you have to use if you use the gas barbecue commercially? And does the system have to be checked regularly for leak-tightness and function? If so, how and by whom? In this article, the GOK blog team will help you to operate commercially used gas barbecues safely.<!--more--><\/p>\n<p style=\"text-align: justify;\">It&#8217;s true everywhere, but especially applicable in hospitality: <strong>time is money<\/strong>. With regard to the equipment, this means: It must be able to work and deliver at the touch of a button. That is why the gas barbecue is so popular, for all those who use it commercially or plan to make it their business in the future.<\/p>\n<p style=\"text-align: justify;\">In addition to functionality, safety is a major topic for every responsible person.How does the LPG system have to be arranged and constructed in order to offer as much <strong>safety as possible<\/strong> for me as the operator and also for my employees? Before we start with this point, however, first of all we deal with the question:<\/p>\n<h5 style=\"text-align: justify;\"><strong>What is covered by the term commercial?<\/strong><\/h5>\n<p style=\"text-align: justify;\">One thing is clear: For example, if you cook steaks and sausages for your family or friends in your leisure time, this is clearly not commercial use. You are not pursuing any commercial purpose, merely a culinary one.<\/p>\n<p style=\"text-align: justify;\">It would be different if you used the gas barbecue, for example,<\/p>\n<ul style=\"text-align: justify;\">\n<li>in a restaurant,<\/li>\n<li>in a snack bar or<\/li>\n<li>in a stall at markets<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">In such cases, as a business owner, you do this for those <strong>commercial reasons<\/strong>, i.e.: You want to earn money and the gas barbecue is your means of doing so.<\/p>\n<h5 style=\"text-align: justify;\"><strong>Sports club: special case?<\/strong><\/h5>\n<p style=\"text-align: justify;\">A special case is when the sports association fires up the gas barbecue at home games to treat the spectators to tasty grilled delicacies.However, as the barbecued food is not generally provided free of charge, this is more of a <strong>commercial<\/strong> use.<\/p>\n<h5 style=\"text-align: justify;\"><strong>Fittings requirements<\/strong><\/h5>\n<p style=\"text-align: justify;\">Once we have defined a distinction between private and commercial, we can now deal with the specific requirements for commercial use of the LPG system.<\/p>\n<div class=\"en_beitrag_box\">\n<p><span class=\"en_like_h3\">You might also be interested in<\/span><\/p>\n<p>Discover more helpful content on this topic.<\/p>\n<p><a href=\"#weiterfuehrend\">See related posts<\/a><\/p>\n<\/div>\n<h5 style=\"text-align: justify;\"><strong>Pressure regulator<\/strong><\/h5>\n<p style=\"text-align: justify;\">The pressure regulator, also referred to as pressure reducer, is the key to the functionality of the entire system. As a business operator, you need a pressure regulator with so-called over-pressure safety device<em>. <\/em>If the gas barbecue is outdoors, we recommend the special &#8220;<a href=\"https:\/\/gok.de\/en\/Low-pressure-regulator-type-EN61-DS-9115090?search=en61ds\" target=\"_blank\" rel=\"noopener\">Grill regulator<\/a>&#8220;.<em><br \/>\n<\/em><\/p>\n<p style=\"text-align: justify;\"><a ref=\"magnificPopup\" href=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2018\/04\/0515000-Druckregler-mit-TAE-fuer-Gewerbe-300x248.jpg\" target=\"_blank\" rel=\"attachment noopener wp-att-4180 noreferrer\"><img decoding=\"async\" class=\"alignleft wp-image-9037\" src=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2018\/04\/0515000-Druckregler-mit-TAE-fuer-Gewerbe-300x248.jpg\" alt=\"Druckregler, der gewerblich auch in R\u00e4umen verwendet werden kann, da er \u00fcber eine thermische Absperreinrichtung (TAE) verf\u00fcgt.\" width=\"192\" height=\"159\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/0515000-Druckregler-mit-TAE-fuer-Gewerbe-300x248.jpg 300w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/0515000-Druckregler-mit-TAE-fuer-Gewerbe-768x634.jpg 768w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/0515000-Druckregler-mit-TAE-fuer-Gewerbe-705x582.jpg 705w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/0515000-Druckregler-mit-TAE-fuer-Gewerbe.jpg 1024w\" sizes=\"(max-width: 192px) 100vw, 192px\" \/><\/a>If the gas barbecue is used in a room, for example, in a snack bar at a folk festival, the <a href=\"https:\/\/gok.de\/en\/Low-pressure-regulator-type-EN61-DS-6515009?search=en61ds\" target=\"_blank\" rel=\"noopener\">pressure regulator also needs a thermal cut-out device<\/a> (image). You can see whether the GOK fitting has one of these by checking for a &#8220;t&#8221; or &#8220;F1-T&#8221; on the type label.<\/p>\n<h5 style=\"text-align: justify;\"><strong>Hose assembly<\/strong><\/h5>\n<p style=\"text-align: justify;\">With the gas hose itself, there is no distinction between private and commercial gas hose \u2013 except for the length (see the following item &#8220;excess flow device&#8221;).As the operator, you should only make sure that the hose assembly is orange, the connections match the fittings to be connected and select the correct length of the gas hose.<\/p>\n<figure id=\"attachment_9038\" aria-describedby=\"caption-attachment-9038\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a ref=\"magnificPopup\" href=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2018\/04\/Schlauchleitungen.jpg\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"wp-image-9038 size-full\" src=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2018\/04\/Schlauchleitungen.jpg\" alt=\"In both private and commercial areas, the operator can choose between a rubber or a plastic hose assembly. Regardless of the material, the business owner&#039;s excess flow device is mandatory with a gas hose length of more than 40 centimetres.\" width=\"1024\" height=\"684\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Schlauchleitungen.jpg 1024w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Schlauchleitungen-300x200.jpg 300w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Schlauchleitungen-768x513.jpg 768w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Schlauchleitungen-705x471.jpg 705w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-9038\" class=\"wp-caption-text\"><strong>In both private and commercial areas, the operator can choose between a rubber or a plastic hose assembly. Regardless of the material, the business owner&#8217;s excess flow device is mandatory with a gas hose length of more than 40 centimetres.<\/strong><\/figcaption><\/figure>\n<h5 style=\"text-align: justify;\"><strong>Excess flow device<\/strong><\/h5>\n<p style=\"text-align: justify;\">On the subject of the gas hose length:If this is longer than 40 centimetres, the business operator requires an excess flow device. It is available as a <a href=\"https:\/\/gok.de\/en\/Excess-flow-valve-low-pressure-0285308?search=schlauchbruchsicherung\" target=\"_blank\" rel=\"noopener noreferrer\">separate component<\/a> as well as <a href=\"https:\/\/gok.de\/en\/Low-pressure-regulator-type-EN61-DS-6515009?search=en61ds\" target=\"_blank\" rel=\"noopener noreferrer\">directly integrated in the pressure regulator<\/a>.<\/p>\n<p><iframe title=\"Hose rupture protection for gas systems - tips, tricks and function in the GOK tutorial\" width=\"640\" height=\"360\" src=\"https:\/\/www.youtube.com\/embed\/qLIu_L-dLSg?list=PL07k85Qz2IkhUsay3NJhiaJ-NeFPQh5eu\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h5 style=\"text-align: justify;\"><strong>Replacement period<\/strong><strong>\u00a0<\/strong><\/h5>\n<p style=\"text-align: justify;\">High temperatures, continuous operation, direct sunlight \u2013 components such as pressure regulator and hose assembly are sometimes subject to intensive load. This is why binding replacement periods exist. These are set out in regulation 110-010 of the German Accident Insurance Act (DGUV 110-010).<\/p>\n<p style=\"text-align: justify;\">At the latest ten years after the date of manufacture, the operator must replace the pressure regulator, hose assembly and other wear parts of the LPG system.<\/p>\n<h5 style=\"text-align: justify;\"><strong>Inspection period<\/strong><\/h5>\n<p style=\"text-align: justify;\">The test intervals for commercial gas barbecues are also set out in DGUV 110-010. According to this, the business owner must appoint a qualified person who:<\/p>\n<ul style=\"text-align: justify;\">\n<li>inspects the system before initial start-up.<\/li>\n<li>performs an inspection after repair work or modifications which may affect operating safety.<\/li>\n<li>inspects the system after operational interruptions lasting longer than one year.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">The inspection period depends on the type of LPG system. All inspection intervals are now specified in a table. You can find this table under <a href=\"https:\/\/publikationen.dguv.de\/widgets\/pdf\/download\/article\/3406\" target=\"_blank\" rel=\"noopener\">6.5 in DGUV Regulation 110-010<\/a>.<\/p>\n<figure id=\"attachment_9036\" aria-describedby=\"caption-attachment-9036\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a ref=\"magnificPopup\" href=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2018\/04\/Pruefung-Gasgrill-Gewerbe.jpg\" target=\"_blank\" rel=\"attachment noopener wp-att-4175 noreferrer\"><img decoding=\"async\" class=\"wp-image-9036 size-full\" src=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2018\/04\/Pruefung-Gasgrill-Gewerbe.jpg\" alt=\"If you use your gas barbecue commercially, you must inspect it or have it inspected based on DGUV V 79.In practice, a test interval of two years has proven to be effective.\" width=\"1024\" height=\"683\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Pruefung-Gasgrill-Gewerbe.jpg 1024w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Pruefung-Gasgrill-Gewerbe-300x200.jpg 300w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Pruefung-Gasgrill-Gewerbe-768x512.jpg 768w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2018\/04\/Pruefung-Gasgrill-Gewerbe-705x470.jpg 705w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-9036\" class=\"wp-caption-text\"><strong>If you use your gas barbecue commercially, you must inspect it or have it inspected based on DGUV 110-010.In practice, a test interval of two years has proven to be effective.<\/strong><\/figcaption><\/figure>\n<h5 style=\"text-align: justify;\"><strong>Tip<\/strong><\/h5>\n<p style=\"text-align: justify;\">Our tip to business owners: take a closer look at <a href=\"https:\/\/publikationen.dguv.de\/widgets\/pdf\/download\/article\/3406\" target=\"_blank\" rel=\"noopener noreferrer\">DGUV 110-010<\/a> if you haven&#8217;t already done so. It is a key collection of useful information for the general use of LPG in the commercial sector \u2013 and is not only limited to gas barbecues, but to various pieces of gas equipment.<\/p>\n<p style=\"text-align: justify;\">All things considered, you should not see such regulations as annoyances to prevent you from operating your actual business. On the contrary, they help you to establish a maximum level of safety. Both for the business owners and their employees as well the guests.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you use a gas barbecue commercially, you must take some things into account: Constant functionality. High load on the device as well as the system and safety for yourself, your employees and your customers. In this article, we explain what the business operator must pay attention to when it comes to pressure regulators, gas hoses, etc., make recommendations and classify the term &#8220;commercial&#8221;.<\/p>\n","protected":false},"author":8,"featured_media":10419,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[395],"tags":[307,285,299,302,286,274,324],"ausgabe":[],"class_list":["post-9873","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-grill-bbq","tag-barbecue","tag-dguv-v-79-en","tag-g-612-en","tag-gas-barbecue","tag-leak-test","tag-replacement","tag-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9873","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/comments?post=9873"}],"version-history":[{"count":1,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9873\/revisions"}],"predecessor-version":[{"id":14530,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9873\/revisions\/14530"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/media\/10419"}],"wp:attachment":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/media?parent=9873"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/categories?post=9873"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/tags?post=9873"},{"taxonomy":"ausgabe","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/ausgabe?post=9873"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}