{"id":9968,"date":"2022-03-24T07:30:49","date_gmt":"2022-03-24T06:30:49","guid":{"rendered":"https:\/\/www.gok-blog.de\/?p=9968"},"modified":"2026-06-15T09:32:31","modified_gmt":"2026-06-15T07:32:31","slug":"how-do-i-get-checkable-dry-run-protection-for-adblue-systems","status":"publish","type":"post","link":"https:\/\/www.gok-blog.de\/en\/how-do-i-get-checkable-dry-run-protection-for-adblue-systems\/","title":{"rendered":"How do I get checkable dry-run protection for AdBlue\u00ae systems?"},"content":{"rendered":"<p>It is every filling station or tank system operator\u2019s nightmare. The tank with AdBlue\u00ae is empty, the pump is drawing air and could be damaged and\/or lead to false bills. Dry-run protection, also known as product shortage protection, prevents this kind of scenario. Such product shortage protection can be provided with the electronic level gauge SmartBox 2 from GOK, and checked using simple means. Since the beginning of 2022, this has been a prerequisite for calibrating such a tank system!<!--more--><\/p>\n<p>Actually \u2013 and the emphasis in this sentence is on \u201cActually\u201d \u2013 it is rarely the case that a tank with a liquid medium runs empty and the <strong>booster pump sucks air<\/strong>. Most operators have an eye on the filling level; either by incorporating electronic or mechanical level gauges (which, in the best case, they can still monitor remotely) or by imposing regular visual inspection intervals on themselves.<\/p>\n<p>Nevertheless, something unexpected can happen at any time and the usual mechanisms do not work. For this reason, dry-run protection is required, in particular for commercially used filling stations and tank systems.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Dry-run_protection_with_SmartBox_2\"><\/span>Dry-run protection with SmartBox 2<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>This kind of safety mechanism is also provided relatively easily, for example with the <a href=\"https:\/\/gok.de\/en\/SmartBox-2-IP54-Typ2-o.Sonde-2826100?search=smartbox\" target=\"_blank\" rel=\"noopener\">electronic level gauge SmartBox 2<\/a>. This allows liquid media such as AdBlue\u00ae, fuel oil, diesel or water to be monitored in non-pressurised tanks.<\/p>\n<p>The SmartBox 2 has <strong>two potential-free relay contacts<\/strong> where you can select the switch points. We describe the advantages that this offers in terms of dry-run protection\/product shortage protection using an example.<\/p>\n<p>Let\u2019s assume that an operator of an AdBlue\u00ae system wants to protect their tank system\u2019s booster pump from drawing air because the tank is empty. If the pump is now controlled using these potential-free relay contacts, it ensures that it no longer pumps when, for example, the tank content falls below 10\u00a0percent of the total volume. If the operator sets the <strong>second switch point<\/strong> to 15\u00a0percent, the pump will only resume operation as soon as the tank content exceeds that value \u2013 after or during refuelling.<\/p>\n<figure id=\"attachment_9959\" aria-describedby=\"caption-attachment-9959\" style=\"width: 900px\" class=\"wp-caption alignnone\"><a ref=\"magnificPopup\" href=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2022\/03\/Anlage-fuer-AdBlue-mit-Trockenlaufschutz-SmartBox-2-GOK-Blog.jpg\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"wp-image-9959 size-full\" src=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2022\/03\/Anlage-fuer-AdBlue-mit-Trockenlaufschutz-SmartBox-2-GOK-Blog.jpg\" alt=\"Operators of AdBlue tank systems or AdBlue filling stations can use SmartBox 2 to provide checkable dry-run protection. The electronic level gauge stops the booster pump when the level falls below a defined filling level. The check is very simple.\" width=\"900\" height=\"557\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Anlage-fuer-AdBlue-mit-Trockenlaufschutz-SmartBox-2-GOK-Blog.jpg 900w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Anlage-fuer-AdBlue-mit-Trockenlaufschutz-SmartBox-2-GOK-Blog-300x186.jpg 300w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Anlage-fuer-AdBlue-mit-Trockenlaufschutz-SmartBox-2-GOK-Blog-768x475.jpg 768w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Anlage-fuer-AdBlue-mit-Trockenlaufschutz-SmartBox-2-GOK-Blog-705x436.jpg 705w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/a><figcaption id=\"caption-attachment-9959\" class=\"wp-caption-text\">Operators of AdBlue\u00ae tank systems or AdBlue\u00ae filling stations can use SmartBox 2 to provide checkable dry-run protection. The electronic level gauge stops the booster pump when the level falls below a defined filling level. The check is very simple. <br \/>Image from <a href=\"https:\/\/pixabay.com\/de\/users\/waid1995-5326289\/?utm_source=link-attribution&amp;utm_medium=referral&amp;utm_campaign=image&amp;utm_content=6937885\" target=\"_blank\" rel=\"noopener\">Waid1995<\/a> on <a href=\"https:\/\/pixabay.com\/de\/?utm_source=link-attribution&amp;utm_medium=referral&amp;utm_campaign=image&amp;utm_content=6937885\" target=\"_blank\" rel=\"noopener\">Pixabay<\/a><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Special_case_calibration_of_AdBlue%C2%AE_system\"><\/span>Special case calibration of AdBlue\u00ae system<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>It has been around since 2014, but it has only really come into focus since the beginning of 2022: the Measurement and Calibration Ordinance (MessEV). Since 2022, the calibration offices in Germany are <strong>only carrying out calibration of AdBlue\u00ae systems<\/strong>, if they have product shortage protection, i.e. dry-run protection, which can be checked using simple means during calibration. The reason for the change in 2022 is that the calibration offices now interpret the MessEV differently.<\/p>\n<p>In concrete terms, this means that anyone who relies on calibration for an AdBlue\u00ae system, for example, will inevitably need the SmartBox 2, with which this easily <strong>checkable product shortage protection<\/strong> can be provided.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Are_all_AdBlue%C2%AE_systems_affected\"><\/span>Are all AdBlue\u00ae systems affected?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>No, not all systems are affected. Only systems subject to <strong>commercial use,<\/strong> such as filling stations, must have checkable dry-run protection as these are the systems that also require calibration.<\/p>\n<p>AdBlue\u00ae tank systems used exclusively within the company, for example in forwarding companies, to supply the company\u2019s own fleet with AdBlue\u00ae, are not affected by this obligation. Operators of non-commercial systems must decide for themselves whether product shortage protection (dry-run protection) is nevertheless sensible for their own system.<\/p>\n<figure id=\"attachment_9964\" aria-describedby=\"caption-attachment-9964\" style=\"width: 900px\" class=\"wp-caption alignnone\"><a ref=\"magnificPopup\" href=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2022\/03\/Tankstelle-AdBlue-Eichung-GOK-Blog.jpg\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"wp-image-9964 size-full\" src=\"https:\/\/b15asa3.myrdbx.io\/wp-content\/uploads\/2022\/03\/Tankstelle-AdBlue-Eichung-GOK-Blog.jpg\" alt=\"Tankstellen mit einer AdBlue-Tankanlage ben\u00f6tigen definitv eine Eichung und daher auch einen pr\u00fcfbaren Trockenlaufschutz, auch Produktmangelsicherung genannt.\" width=\"900\" height=\"506\" title=\"\" srcset=\"https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Tankstelle-AdBlue-Eichung-GOK-Blog.jpg 900w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Tankstelle-AdBlue-Eichung-GOK-Blog-300x169.jpg 300w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Tankstelle-AdBlue-Eichung-GOK-Blog-768x432.jpg 768w, https:\/\/www.gok-blog.de\/wp-content\/uploads\/2022\/03\/Tankstelle-AdBlue-Eichung-GOK-Blog-705x396.jpg 705w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/a><figcaption id=\"caption-attachment-9964\" class=\"wp-caption-text\">Filling stations with an AdBlue\u00ae tank system definitely need calibration and therefore also checkable dry-run protection, also called product shortage protection.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Checking_dry-run_protection\"><\/span>Checking dry-run protection<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>So far we have talked about \u201ccheckable dry-run protection\u201d or \u201ccheckable product shortage protection\u201d. But what actually is the check and who does the check? We have information from several German calibration offices, stating that a <strong>very simple function check<\/strong> is enough. In relation to a system with SmartBox 2, this means: simply pull the probe out of the liquid. This simulates that the tank is empty and the booster pump must subsequently stop operation.<\/p>\n<p>On the one hand, this function is of course checked by the <strong>representative from the calibration office<\/strong>, who is ultimately also responsible for the calibration. On the other hand, we would recommend that the operators themselves have the product shortage protection checked by a specialist from time to time.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Approval_required\"><\/span>Approval required?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Although it is frequently necessary for technical devices to have a special approval, that is not the situation in this case. In the context of checkable product shortage protection (dry-run protection), there is <strong>no need for any specific approval<\/strong>, for example from the DIBt (German Institute of Building Technology).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>It is every filling station or tank system operator\u2019s nightmare. The tank with AdBlue\u00ae is empty, the pump is drawing air and could be damaged and\/or lead to false bills. Dry-run protection, also known as product shortage protection, prevents this kind of scenario. Such product shortage protection can be provided with the electronic level gauge SmartBox 2 from GOK, and checked using simple means. Since the beginning of 2022, this has been a prerequisite for calibrating such a tank system!<\/p>\n","protected":false},"author":8,"featured_media":9955,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[398],"tags":[313,296,333,324],"ausgabe":[],"class_list":["post-9968","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tank-liquid-media","tag-content-measurement","tag-level-indicator","tag-smartbox-en","tag-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/comments?post=9968"}],"version-history":[{"count":1,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9968\/revisions"}],"predecessor-version":[{"id":14571,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/posts\/9968\/revisions\/14571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/media\/9955"}],"wp:attachment":[{"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/media?parent=9968"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/categories?post=9968"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/tags?post=9968"},{"taxonomy":"ausgabe","embeddable":true,"href":"https:\/\/www.gok-blog.de\/en\/wp-json\/wp\/v2\/ausgabe?post=9968"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}